NEW QUESTION 22
Which statement about M-LAG setup is true?
- A. When combined with IRF, M-LAG will allow you to aggregate ports coming from clustered HPE Synergy Virtual Connect modules.
- B. M-LAG for HPE Synergy can be either single-homed or multi-homed, while for HPE BladeSystem only single-homed.
- C. sFLOW cannot be enabled if M-LAG is configured between HPE Synergy Virtual Connect modules in the same frame.
- D. M-LAG has to be defined manually for HPE BladeSystem, but it is automatically configured for HPE Synergy.
Answer: A
NEW QUESTION 23
Refer to the exhibit.
You discovered that one of the profiles is not compliant with the server profile template. What could cause this profile to be inconsistent with the server profile template?
- A. Changes to the server profile were implemented directly on the server profile.
- B. The server was powered off or rebooted recently and IL0 did not reconnect to HPE OneView.
- C. Network connectivity for HPE Synergy Compute Module was changed outside HPE OneView.
- D. HPE OneView was restored from a backup that created ^consistency with the server profile template.
Answer: C
NEW QUESTION 24
Which statement about a Logical Enclosure for HPE BladeSystem is Hue?
- A. A logical enclosure must be created only for monitored HPE BladeSystem C700O enclosures.
- B. A logical enclosure can contain a mix of HPE BladeSystem c7000 and C3000 enclosures.
- C. A logical enclosure is created automatically, and it is always based on a single enclosure.
- D. A logical enclosure can have between 1 to 5 HPE BladeSystem c7000 enclosures.
Answer: C
NEW QUESTION 25
Refer to the exhibit.
Your customer created multiple networks in HPE OneView, but only Eth-1 is available to be used within a server profile. What is a likely cause of this situation?
- A. The other networks are not added to the Logical Interconnect Group configuration.
- B. The other networks are configured with a purpose other than General or Management.
- C. The other networks have Private Network' selected, which hides them from Compute Modules.
- D. The other networks are not configured with the required Smart Link parameter.
Answer: C
NEW QUESTION 26
Which statement about an HPE OneView server profile is true?
- A. A server profile created for a specific server hardware type cannot be moved to a server with a different server hardware type.
- B. A server profile can be used to configure a local storage controller, but cannot be used to configure SAN-based storage.
- C. A server profile can be used to update firmware and drivers when the operating system on the server is up and running.
- D. A server profile can be created only for HPE BladeSystem, HPE Synergy, and HPE Superdome Flex servers.
Answer: B
NEW QUESTION 27
Refer to the exhibit.
Your customer wants to define a Logical Interconnect Group (UG) and set the redundancy of the master modules to highly available, but this option is not available. What is a possible reason?
- A. There are not sufficient frames for highly available setup.
- B. Firmware on the master modules is too low to support highly available setup.
- C. Some master modules only support a redundant setup.
- D. A dedicated license must be added to HPE OneView to enable this feature.
Answer: C
NEW QUESTION 28
Your customer added HPE Primera to HPE OneVlew and enabled volume provisioning on all storage pools.
For security reasons, the customer wants to disable volume provisioning using HPE OneView on a specific storage pool.
How can this task be completed?
- A. The storage pool should be marked as read-only using HPE OneView.
- B. The storage pool should be disabled using the array management tool.
- C. The storage pool should be removed from HPE OneView using a PowerShell script.
- D. The storage pool state should be changed to discovered using HPE OneView.
Answer: B
NEW QUESTION 29
For HPE Primera, match each task with the management tool that can be used to perform it.
Answer:
Explanation:
NEW QUESTION 30
How can your customer implement HPE OneView so that it can be used to manage an HPE ProLiant server and HPE BladeSystem?
- A. As an application running on the server with Windows system.
- B. As an application running on the server with CentOS Linux system
- C. As a virtual appliance running on the supported hypervisor.
- D. As a physical appliance based on HPE ProLiant 360 Gen 10.
Answer: D
NEW QUESTION 31
A customer has to deploy 21 HPE Synergy Compute Modules in a boot from SAN setup. How this task can be simplified while keeping the profile consistent?
- A. Boot volumes can be prepared in advance and later presented as shared volumes to the Compute Modules.
- B. An existing volume can be replicated automatically when creating a server profile.
- C. Boot volumes can be created on demand and defined in the server profile template.
- D. single SAN volume can be created and utilized by all HPE Synergy Compute Modules.
Answer: C
NEW QUESTION 32
Your customer wants to use HPE OneView for VMware vCenter Server to simplify management of their VMware cluster running on HPE Synergy. The customer is concerned with the cost of additional licenses.
How will you explain licensing rules for this product?
- A. As long as the customer has HPE OneVtew Global Dashboard deployed, HPE OneView for VMware vCenter Server does not require any additional licenses.
- B. One HPE OneView for VMware vCenter Server license is required per HPE Synergy frame if more than
10 Compute Modules are installed in the frame. - C. If the number of the HPE Synergy Compute Modules installed in HPE Synergy frame is less than 10, no license is required to use HPE OneView tor VMware vCenter Server.
- D. As long as the server is managed using HPE OneView. the customer can use HPE OneView for VMware vCenter Server without additional licenses.
Answer: B
NEW QUESTION 33
Click the option that must be configured for an HPE OneView when an HPE storage system is connected directly to an HPE Synergy frame.
Answer:
Explanation:
NEW QUESTION 34
You want to put two FlexNlCs into a single Link Aggregation Group within a server profile. What Is a prerequisite for this setup?
- A. The Compute Module profile must have exactly two connections defined.
- B. Both FlexNlCs must be connected to the same network.
- C. An upgrade license must be purchased and deployed.
- D. The sFlow option must be enabled and configured.
Answer: D
NEW QUESTION 35
You try to add an HPE Primera array to HPE OneView, but you get a connectivity error. However, you can connect to the array using SSMC. What should you verify before adding HPE Primera to HPE OneView?
- A. whether array management using HPE OneView is enabled in SSMC.
- B. whether the appropriate license for HPE Primera Is available in HPE OneView.
- C. whether WSAPI service is enabled on HPE Primera array.
- D. whether there are at least two Fibre Channel networks defined in HPE OneView.
Answer: C
NEW QUESTION 36
Which statement about a server profile for an Apollo system is true?
- A. Virtual WWNs and MAC addresses can be defined
- B. UEFI optimized is the only available boot mode
- C. Fibre Channel connections can be defined
- D. Enclosure Group Is automatically selected
Answer: A
NEW QUESTION 37
You configured downlink aggregation for one of the HPE Synergy Compute Modules in an environment by placing two connections in the same Link Aggregation Group. After you made the changes to the server profile, its status changed to critical.
What can be done to fix this issue?
- A. The teaming or bonding driver in the server OS must be configured to enable the LACP and to form the LAG correctly.
- B. Link Aggregation Group functionality should be enabled in advanced properties of the Logical Interconnect.
- C. The server profile for a given HPE Synergy compute module should be reapplied, then the Compute Module should be rebooted.
- D. Ensure that the Link Aggregation Group time-out value matches the server set values.
Answer: B
NEW QUESTION 38
......
Verified HPE2-T37 dumps Q&As - 100% Pass from ITExamDownload: https://www.itexamdownload.com/HPE2-T37-valid-questions.html
Pass HPE2-T37 Exam in First Attempt Guaranteed 2021 Dumps: https://drive.google.com/open?id=1zQaArVVsYlXFww4aW5JpSc_3RR29o3PS