NEW QUESTION 75
Which is a valid connectivity option for a FlexPod?
Note some of these may also be 'valid' options outside of a FlexPod architecture but do not specifically meet FlexPod scalability and availability requirements.

  • A. UCS C-Series direct attach FAS
  • B. UCS B-Series > 2232PP FEX > UCS FI > Nexus 5548 < FAS
  • C. UCS C-Series > 2232PP FEX > UCS FI > Nexus 5548 < FAS
  • D. UCS B-Series direct attach FAS
  • E. UCS C-Series > Nexus 3048 < FAS
  • F. UCS B-series > UCS FI > 2232PP FEX > Nexus 5548 < FAS
  • G. UCS B-Series > UCS FI > Catalyst 3750 < FAS

Answer: C,E

 

NEW QUESTION 76
Which set of commands maps VLAN 100 to VSAN 100?

  • A. Nexus 5000-B# configure terminal Nexus 5000-B(config-vsan) # vlan 100 Nexus 5000-B (config-vsan)# vsan 100 name vsan100
  • B. Nexus 5000-A#configure terminal Nexus 5000-B (config) # vsan database Nexus 5000-A (config)# vsan 100 Nexus 5000-A (config-vsan) # fcoe vsan 100
  • C. Nexus 5000-A#configure terminal Nexus 5000-A (config) # vlan 100 Nexus 5000- A (config-vlan_ #fcoe vsan 100
  • D. Nexus 5000-B# configure terminal Nexus 5000-B (config) # vsan database Nexus 5000-B (config-vsan)# vsan 100 Nexus 5000-B(config- vsan) #vsan 100 name FCoE-VLAN 100

Answer: C

 

NEW QUESTION 77
You have a NetApp clustered Data ONTAP storage system and vSphere 6 cluster. You discover that VMware VAAI for NFS is not showing as enabled on one of the five ESXi hosts in your vSphere cluster.
In this scenario, what must you do to enable VAAI for NFS on that ESXi host?

  • A. Set the DataMover. HardwareAcceleratedInit advanced setting to 0 on the ESXi host.
  • B. Install the NetApp NFS Plug-in for VMware VAAI on the ESXi host.
  • C. Enable NFSv3 on the storage system.
  • D. Enable VMware vStorage for NFS on the NetApp SVM.

Answer: C

 

NEW QUESTION 78
Exhibit:

Your customer has a FlexPod VMware solution deployed with NFS datastores. As shown in the exhibit, the links between the Fabric Interconnects and storage controllers are single-mode interface groups with autorevert set to true, hosting a single access LIF. NFS I/O is currently going through fabric A to ST-A. The customer wants to use both fabrics for NFS I/O.
In this scenario, what will accomplish this task?

  • A. Configure VMware hosts to utilize an NFS LIF on ST-B that is connected to fabric A.
  • B. Configure VMware hosts to use a new datastore with an NFS LIF on ST-B connected to fabric B.
  • C. Add two physical links between SW-A and SW-B.
  • D. Migrate the existing LIF that is used for NFS I/O on ST-A to its HA partner ST-B.

Answer: B

 

NEW QUESTION 79
Which backup type stores Service Profile information as a small editable file?

  • A. Full Backup
  • B. All Configurations
  • C. System Configuration
  • D. Logical Configuration

Answer: D

 

NEW QUESTION 80
You run NetApp ConfigAdvisor against you FAS8060A storage system. The report states that the flow control settings for ports e0a on each node are incorrect.
Which set of commands will correct this problem?

  • A. network interface modify- node netapp-01 -port e0a -flowcontrol -admin none network interface modify -node netapp-02 -port e0a -flowcontrol - admin none
  • B. network port modify- node netapp-01 port e0a-flowcontrol-admin full network port modify- node netapp-02 port e0a-flowcontrol-admin full
  • C. network interface modify- node netapp-01 port e0a-flowcontrol-admin full network interface modify- node netapp-02 port e0a-flowcontrol-admin full
  • D. network port modify -node netapp-01 -port e0a -flowcontrol-admin none network port modify -node netapp-02 -port e0a -flowcontrol-admin none

Answer: D

 

NEW QUESTION 81
You are installing a FlexPod Express solution with a NetApp AFF A250 at a customer's remote site.
In this scenario, which two devices are required to provide an NFS v3 datastore? (Choose two.)

  • A. Cisco Nexus 3000 Switches
  • B. NetApp BES-53248 Switches
  • C. Cisco UCS 6324 Fabric Interconnects
  • D. Cisco UCS 6454 Fabric Interconnects

Answer: A,C

 

NEW QUESTION 82
What is the maximum number of nodes that a NetApp SAN cluster supports?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 83
Exhibit:

You just configured a new Storage Virtual Machine named SVM1 on your NetApp cluster to serve up NFS datastores to an ESX cluster.
Your VMware administrator tells you that the ESX servers are unable to access the datastore that you created on node flexpod1-san01-01. The IP address of one of the ESX servers is 10.33.128.100.
Referring to the exhibit, which command would you use to troubleshoot this problem?

  • A. ~network ping -lif flexpod1-san01-01 mgmt1 -vserver flexpod1-san01 -destination 10.33.128.100~
  • B. ~network ping -lif cluster mgmt -vserver flexpodl-san01 - destination 10.33.128.100~
  • C. ~network ping -node flexpod1-san01-01 -destination 10.33.128.100~
  • D. ~network ping -lif nfs1 -vserver svm1 -destination 10.33.128.100~

Answer: D

 

NEW QUESTION 84
Which four items are required in order to create a Gold Master Boot LUN to automate the provisioning of Hyper-V hosts using the built-in LUN cloning capabilities of NetApp storage? (Choose four.)

  • A. Configuration of the Server OS and hotfix installation
  • B. Create additional virtual fibre channel (vfc) interfaces for the Nexus 5500
  • C. Create a new interface group on the NetApp Cluster
  • D. Creation of a LUN for the Gold Master Boot LUN
  • E. Creation of a service profile and zoning for Gold Master Boot LUN
  • F. SysPrep of the server operating system

Answer: A,D,E,F

 

NEW QUESTION 85
Exhibit:

An administrator has a FlexPod solution configured for Microsoft Hyper-V 2012 R2. The UCS blade servers are configured for SAN boot, and all zoning and LUN mapping for a single 50 GB LUN have been configured.
When selecting the install disk during the Windows installation, the symptoms and error shown in the exhibit are displayed.
What should the administrator do to solve the problem?

  • A. Delete the extra LUNs that were created.
  • B. Install the Cisco VIC storage miniport driver for Windows 2012 R2.
  • C. Configure a single path to the LUN for the duration of the Windows installation process.
  • D. Change the LUN OS type to oeWindows 2008 or later.

Answer: B

 

NEW QUESTION 86
Exhibit:

Which hardware component is shown in the exhibit?

  • A. FI
  • B. FEX
  • C. VIC
  • D. IOM

Answer: C

 

NEW QUESTION 87
You are asked to increase read performance for a single aggregate; however, there are no PCI-e slots available in the NetApp cluster nodes.
In this scenario, which feature meets these requirements?

  • A. Flash Cache
  • B. Advanced Drive Partitioning
  • C. Thin Provisioning
  • D. Flash pool

Answer: D

 

NEW QUESTION 88
You are asked to verify your MPIO settings for your ONTAP FlexPod solution. You are using VMware ESXi 6 and FCP as the storage protocol.
In this scenario, which MPIO setting would you use on the ESXi host?

  • A. fixed path
  • B. fixed path with array preference
  • C. round robin
  • D. most recently used

Answer: C

 

NEW QUESTION 89
How do the Fabric Interconnect ports connecting to the 2232PP FEX have to be configured?

  • A. In UCS Manager, the FI ports connecting to the FEX must be set as type 'Network'
  • B. In UCS Manager, the FI ports connecting to the FEX must be set as type 'FEX'
  • C. In UCS Manager, the FI ports connecting to the FEX must be set as type 'Uplink'
  • D. In UCS Manager, the FI ports connecting to the FEX must be set as type 'Auto'
  • E. In UCS Manager, the FI ports connecting to the FEX must be set as type 'Server'

Answer: E

 

NEW QUESTION 90
A Cisco UCS system is operating in FC End-Host Mode. The fabric Interconnects are uplinked into Nexus 5672UP switches using native FC. The service profiles are unable to boot from SAN using FC.
When executing the show flogi database command on the Nexus switches, only the Fabric Interconnect port WWNs are visible. No service profile WWNs are shown.
What caused this issue?

  • A. The zoning on the Nexus switches is incorrect.
  • B. The Nexus switches do not have NPIV enabled.
  • C. The Nexus switches do not have NPV enabled.
  • D. The Nexus must be configured for FCoE instead of native Fibre Channel.

Answer: B

 

NEW QUESTION 91
An administrator has a FlexPod solution and is using OnCommand Unified Manager and OnCommand Performance Manager to monitor the FlexPod environment. Full integration has previously been configured between the two OnCommand virtual appliances; however, new performance issues are not being seen in the OnCommand Unified Manager dashboard.
In this scenario, which two settings should the administrator verify? (Choose two.)

  • A. Ensure that the Event Publisher user credentials are entered correctly on the OnCommand Performance Manager appliance.
  • B. Ensure that network connectivity exists between the two virtual appliances.
  • C. Ensure that OnCommand Performance Manager is licensed for use with OnCommand Unified Manager.
  • D. Ensure that the NetApp cluster is configured to forward SNMP data to OnCommand Performance Manager.

Answer: A,C

 

NEW QUESTION 92
Which aggregates should be disabled for data aggregates?

  • A. iSCSI
  • B. FCP
  • C. Snapshot copies
  • D. SnapMirror copies

Answer: C

 

NEW QUESTION 93
......

Focus on NS0-176 All-in-One Exam Guide For Quick Preparation: https://www.itexamdownload.com/NS0-176-valid-questions.html