NEW QUESTION # 33
Sprinkler heads used in computer rooms activate at what temperature?
- A. 27 °C (81 °F)
- B. 70 C (158 °F)
- C. 57 °C (135 °F)
- D. Only on direct contact with a flame
Answer: C
Explanation:
Sprinkler heads used in computer rooms activate at 57 °C (135 °F), which is the standard temperature rating for ordinary sprinklers. This is the temperature at which the heat-sensitive element of the sprinkler head, such as a glass bulb or a fusible link, breaks or melts, allowing water to flow from the sprinkler. Sprinkler heads are designed to activate only when exposed to a fire, not to ambient temperature fluctuations. Therefore, sprinkler heads should be installed at a sufficient distance from the heat sources, such as servers, racks, or ducts, to avoid accidental activation. Sprinkler heads should also be selected and installed in accordance with the relevant standards and codes, such as NFPA 13 and NFPA 75.
References:
1: CDCP Preparation Guide, page 24, section 2.4.3 2: Sprinkler Systems in Data Centers3, page 1, section 1 4:
Data Center Fire Protection5, page 1, section 2 6: Data Center Sprinkler System Design7, page 1, section 1
NEW QUESTION # 34
is the degree to which a system or component is operational and accessibility when required for use.
- A. Reliability
- B. Agility
- C. Availability
- D. Scalability
Answer: C
Explanation:
Availability is the degree to which a system, product or component is operational and accessible when required for use. It is one of the attributes of reliability, which is the ability of a system or component to perform its required functions under stated conditions for a specified period of time. Availability can be calculated as the ratio of the expected value of the uptime (the time when the system is functional) to the total time (uptime plus downtime) of a system or component. Availability can also be influenced by factors such as maintainability, fault tolerance, redundancy, diagnostics, and logistics.
References: EPI Data Centre Professional (CDCP) Preparation Guide, page 8; Availability - Wikipedia; Reliability - ISO 25000.
NEW QUESTION # 35
What should be considered when implementing hot- or cold-aisle containment in an existing computer room?
- A. It creates potential issues with the existing fire suppression system(s).
- B. Equipment will get too hot at the rear (back) of the rack potentially resulting in more ICT hardware failures.
- C. It will be more difficult to install power and network cabling in the contained area.
- D. The delta-T of the equipment will increase too much causing reliability issues.
Answer: A
Explanation:
Hot- or cold-aisle containment is a strategy to improve the cooling efficiency and reduce the energy consumption of data centers by isolating the hot exhaust air from the cold supply air. However, implementing this strategy in an existing computer room may create potential issues with the existing fire suppression system (s), such as:
*The containment barriers may interfere with the distribution and activation of the fire suppression agents, such as water, gas, or aerosol, and reduce their effectiveness in extinguishing a fire.
*The containment barriers may create pockets of high temperature and pressure that could damage the equipment or the containment structure itself in the event of a fire.
*The containment barriers may obstruct the access and visibility of the fire detection and alarm devices, such as smoke detectors, heat sensors, or manual call points, and delay the response time of the fire suppression system(s).
*The containment barriers may violate the local fire codes and regulations that specify the minimum clearance and ventilation requirements for the data center.
Therefore, when implementing hot- or cold-aisle containment in an existing computer room, it is important to consider the impact on the existing fire suppression system(s) and take appropriate measures to ensure the safety and compliance of the data center, such as:
*Consulting with the fire authorities and the fire suppression system vendor to assess the compatibility and suitability of the containment solution with the existing fire suppression system(s).
*Modifying or upgrading the existing fire suppression system(s) to accommodate the containment solution, such as relocating or adding fire suppression devices, adjusting the discharge rate and pressure, or installing a secondary fire suppression system within the contained area.
*Installing fire-rated containment barriers that can withstand high temperatures and resist the spread of fire and smoke, and that have self-closing or automatic release mechanisms in case of a fire.
*Installing fire detection and alarm devices within the contained area and ensuring their proper integration and communication with the existing fire suppression system(s).
*Conducting regular testing and maintenance of the fire suppression system(s) and the containment solution to ensure their functionality and reliability.
References: EPI Data Centre Framework, Module 4: Fire Protection, page 10-11. EPI Data Centre Professional (CDCP) Reference Materials, page 66-67. 1, 2, 3.
NEW QUESTION # 36
Which one of the following is a device that uses circulating chilled water to remove heat?
- A. Computer Room Air System Unit (CRAS)
- B. Computer Room Air Suspension Unit (CRAS)
- C. Computer Room Air Suppression Unit (CRAS)
- D. Computer Room Air Handling Unit (CRAH)
Answer: D
Explanation:
A computer room air handling unit (CRAH) is a device that uses circulating chilled water to remove heat from the data center environment. A CRAH consists of a fan, a coil, and a filter. The fan draws the warm air from the data center and passes it through the coil, where the heat is transferred to the chilled water. The chilled water is supplied by a chiller or a cooling tower, and the cooled air is returned to the data center. A CRAH is different from a computer room air conditioning unit (CRAC), which uses a refrigerant instead of chilled water to cool the air.
References:
*EPI Data Centre Professional (CDCP) Preparation Guide, page 36
*Chilled Water Systems: Applications and Common Uses
*The Principles of Basic Refrigeration: What is a chiller?
NEW QUESTION # 37
What is the main advantage of busbar trunking compared to stand electrical cabling?
- A. Busbar trunking has a fixed power rating.
- B. Busbar trunking allows for flexibility.
- C. Busbar trunking can be located both overhead and under the raised floor.
- D. Busbar trunking is less expensive.
Answer: B
Explanation:
Busbar trunking systems are a method of power distribution using rigid copper or aluminium conductors to distribute the power around a building. Busbar trunking systems have many advantages over cables, such as lower space requirements, higher short-circuit strength, lower fire load, and easier installation. One of the main advantages of busbar trunking is that it allows for flexibility in terms of power transmission and distribution. Busbar trunking systems can be easily relocated, modified, or expanded to accommodate changes in the building layout or load demand. Busbar trunking systems can also be fitted with various components, such as tap-off units, elbows, tees, and end feed units, to provide power to different locations and consumers.
Busbar trunking systems can also be installed both overhead and under the raised floor, depending on the design and preference of the building.
References: Why I prefer busbar trunking systems more than cables | EEP, Why should you choose Busbar over Cable? - E+I Eng, Busbar VS Cables for Riser Applications - An Electrical Engineer.
NEW QUESTION # 38
Which one of the following represents the three elements (oxygen, heat and fuel) to interact in order for the fire to exist?
- A. The Fire Hexagon
- B. The Fire Class
- C. The Fire Triangle
- D. The Fire Technology
Answer: C
Explanation:
The fire triangle is a simple model that illustrates the three elements a fire needs to ignite: heat, fuel, and an oxidizing agent (usually oxygen). A fire naturally occurs when the elements are present and combined in the right mixture. A fire can be prevented or extinguished by removing any one of the elements in the fire triangle.
References: EPI Data Centre Professional (CDCP) Preparation Guide, page 9; Fire triangle - Wikipedia; The Fire Triangle Explained - Fire Action
NEW QUESTION # 39
IP protection grades consist of two numbers.
Which levels of protection do they describe and what is the best protection?
- A. First digit; protections against the ingress of solid objects. Second digit; protection against ingress of water/fluids. The lower the number the better the level of protection.
- B. First digit; protections against the ingress of water/fluids. Second digit; protection against ingress of solid objects. The lower the number the better the level of protection.
- C. First digit; protections against the ingress of solid objects. Second digit; protection against ingress of water/fluids. The higher the number the better the level of protection.
- D. First digit; protections against the ingress of water/fluids. Second digit; protection against ingress of solid objects. The higher the number the better the level of protection.
Answer: C
Explanation:
IP protection grades are a way of showing the effectiveness of electrical enclosures in blocking foreign bodies such as dust, moisture, liquids, and accidental contact. IP stands for Ingress Protection or International Protection, and it is defined by the international standard IEC 60529. IP ratings consist of the letters IP followed by two digits and an optional letter. The first digit indicates the level of protection the enclosure provides against access to hazardous parts and the ingress of solid foreign objects. The second digit indicates the level of protection the enclosure provides against the ingress of water or fluids. The higher the number, the better the level of protection. For example, IP65 means the enclosure is dust-tight and can withstand water jets from any direction. IP68 means the enclosure is dust-tight and can be submerged in water under specified conditions.
References: EPI Data Centre Training Framework, CDCP Preparation Guide, IP code - Wikipedia, [IP Ratings Explained | Ingress Protection Rating | IP Codes | Updated 2022]
NEW QUESTION # 40
Which one of the following is an Audible Signaling and Notification Device?
- A. Strobes
- B. Alarms
- C. Sirens
- D. Clocks
Answer: C
Explanation:
According to the CDCP Preparation Guide, an audible signaling and notification device is a device that produces a sound to alert or notify the occupants of a data center of an event or condition. Sirens are examples of such devices, as they can emit loud and distinctive tones to warn of fire, emergency, or security incidents.
Strobes, on the other hand, are visual signaling and notification devices that produce flashes of light to attract attention or convey information. Alarms and clocks are not specific types of devices, but rather general terms that can refer to various audible or visual devices.
References: CDCP Preparation Guide, page 30. Audible Visual Notification | System Sensor | Honeywell.
Audible-Visual Signaling Devices - AutomationDirect.
NEW QUESTION # 41
Which one of the following is an example of Direct Cost?
- A. Reduced customer satisfaction
- B. Damaged brand perception
- C. Legal fees
- D. Negative public relations
Answer: C
Explanation:
Legal fees are an example of direct cost because they can be directly attributed to a specific project, product, or service. Legal fees are incurred for the purpose of obtaining legal advice, drafting contracts, resolving disputes, or complying with regulations related to the core business activity. Legal fees are not general overhead expenses that are shared by multiple cost objects.
References: EPI Data Centre Training Framework, CDCP Preparation Guide, Direct Cost - Overview, Examples, Tax Implications
NEW QUESTION # 42
Which Class of Fires involves ordinary combustible materials such as paper, wood and cloth?
- A. Class B
- B. Class A
- C. Class D
- D. Class K
Answer: B
Explanation:
According to the CDCP Preparation Guide, Class A fires involve ordinary combustible materials such as paper, wood and cloth. These materials leave behind ash or embers when they burn. Class A fires can be extinguished by water or other cooling agents that reduce the temperature of the fuel below its ignition point.
References: CDCP Preparation Guide, page 30. Basics of Fire Protection in a Data Center. 3 Levels of Data Center Fire Protection Standards. Three Levels of Data Center Fire Protection.
NEW QUESTION # 43
The three elements of the fire triangle are,and. (Choose three.)
- A. Water
- B. Fuel
- C. Heat
- D. Earth
- E. Oxygen
Answer: B,C,E
Explanation:
The fire triangle is a simple model that illustrates the three elements that a fire needs to ignite and sustain:
oxygen, heat, and fuel. Oxygen is the oxidizing agent that enables the combustion reaction, heat is the energy source that raises the temperature of the fuel to its ignition point, and fuel is the material that reacts with oxygen and releases heat and light. Removing any one of these elements can extinguish a fire. For example, water can reduce the heat and the oxygen, sand or soil can smother the fuel and the oxygen, and fire extinguishers can displace the oxygen or lower the temperature.
References: EPI Data Centre Professional (CDCP) Reference Materials, page 66. EPI Data Centre Framework, Module 4: Fire Protection, page 4. 1, 2, 3.
NEW QUESTION # 44
Which of statements below is true?
- A. Single-mode cabling is more expensive than multi-mode cabling.
- B. Single-mode cabling can use both LED and laser as a light source.
- C. Multi-mode cabling is more expensive than single-mode cabling.
- D. Multi-mode cabling can cross longer distances.
Answer: A
Explanation:
Single-mode cabling and multi-mode cabling are two types of fiber optic cables that differ in their core diameter, wavelength, light source, bandwidth, distance, and cost. Single-mode cabling has a smaller core diameter and uses a laser as a light source, which enables it to transmit data over longer distances and higher bandwidths. However, single-mode cabling is also more expensive than multi-mode cabling, because it requires more precise alignmentand splicing, and more costly light sources and connectors. Multi-mode cabling has a larger core diameter and uses LEDs or VCSELs as a light source, which makes it cheaper and easier to install and maintain. However, multi-mode cabling also has a shorter distance and lower bandwidth than single-mode cabling, because it suffers from more modal dispersion and attenuation.
References:
1: Data Center Cabling: Single Mode vs Multimode Fibers2, page 1, section 1 3: Single Mode vs Multimode Fiber Cable Guide4, page 1, section 1 5: Single-Mode vs. Multi-Mode Fiber Cables: Explained6, page 1, section 1 7: 2 Types of Fiber Optic Cable: Single Mode vs. Multimode Fiber8, page 1, section 1
NEW QUESTION # 45
Which one of the following is an Objective of Data Center Fire Protection?
- A. Suppression
- B. Depression
- C. Information
- D. Representation
Answer: A
Explanation:
The objective of data center fire protection is to suppress or extinguish a fire before it can cause significant damage to the equipment, personnel, or business continuity. Fire suppression systems are designed to reduce the heat, oxygen, or fuel elements of the fire triangle, and to limit the spread of fire and smoke. Fire suppression systems can be classified into two types: water-based and gas-based. Water-based systems include sprinklers, mist, and water spray systems, which use water as the extinguishing agent. Gas-based systems include inert gas, halocarbon, and clean agent systems, which use gases or chemicals as the extinguishing agent. The choice of fire suppression system depends on several factors, such as the fire risk, the type of fuel, the environmental impact, the reliability, the cost, and the compatibility with the data center equipment and operations.
References:
*EPI Data Centre Professional (CDCP) Preparation Guide, page 31
*A Comprehensive Approach To Data Center Fire Safety
NEW QUESTION # 46
How many monitoring points should be used in Temperature Measurement?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
Explanation:
According to the EPI Data Centre Professional (CDCP®) Reference Materials, the recommended number of monitoring points for temperature measurement in a data centre is 3 per rack: one at the top, one at the middle, and one at the bottom1. This is to ensure that the temperature distribution within the rack is uniform and within the acceptable range for the equipment. The temperature sensors should be placed at the front of the rack, where the air enters the equipment, and not at the back, where the hot air exits1.
References: 1: EPI Data Centre Professional (CDCP®) Reference Materials, page 23.
NEW QUESTION # 47
An optical fiber cable comes with the specifications 50/125 um.
What do the numbers represent?
- A. The first number represents the required distance to single-phase power cabling; the second number represents the required distance to three-phase cabling.
- B. The first number represents the diameter of the core; the second number represents the diameter of the cladding in microns.
- C. The first number represents the distance for a 10 Gb/s connection; the second number represents the distance for a 1 Gb/s connection.
- D. The first number represents the diameter of the core; the second number represents the actual diameter cable including the buffer and jacket.
Answer: B
Explanation:
Optical fiber cables are composed of a core, a cladding, and a coating. The core is the central part of the fiber that carries the light signal. The cladding is the layer surrounding the core that reflects the light back into the core and prevents signal loss. The coating is the protective layer that covers the cladding and provides mechanical strength and environmental protection. The specifications of an optical fiber cable indicate the dimensions of the core and the cladding in microns (m), which are one millionth of a meter. For example, a
50/125 m cable has a core diameter of 50 m and a cladding diameter of 125 m. The coating diameter is usually
250 m, but it is not part of the specifications.
References: Multimode Optical Fiber Selection & Specification - Corning, Optical Fiber OM3 (50/125µm Multimode Fiber), 50/125 Graded-Index OM2 Optical Fiber - OFS
NEW QUESTION # 48
Which one of the following is an Objective of Data Center Fire Protection?
- A. Suppression
- B. Depression
- C. Information
- D. Representation
Answer: A
Explanation:
The objective of data center fire protection is to suppress or extinguish a fire before it can cause significant damage to the equipment, personnel, or business continuity. Fire suppression systems are designed to reduce the heat, oxygen, or fuel elements of the fire triangle, and to limit the spread of fire and smoke. Fire suppression systems can be classified into two types: water-based and gas-based. Water-based systems include sprinklers, mist, and water spray systems, which use water as the extinguishing agent. Gas-based systems include inert gas, halocarbon, and clean agent systems, which use gases or chemicals as the extinguishing agent. The choice of fire suppression system depends on several factors, such as the fire risk, the type of fuel, the environmental impact, the reliability, the cost, and the compatibility with the data center equipment and operations.
References:
*EPI Data Centre Professional (CDCP®) Preparation Guide, page 31
*A Comprehensive Approach To Data Center Fire Safety
NEW QUESTION # 49
Which source is used in fiber cable to transmit data?
- A. Signals
- B. Pulse
- C. Light
- D. Electric
Answer: C
Explanation:
Fiber-optic cables use light as the source to transmit data. Light pulses are modulated to carry information through an optical fiber. The light is confined in the core of the fiber by total internal reflection at the core-cladding interface. The light travels along the fiber with minimal loss or interference, making it suitable for long-distance and high-bandwidth applications.
References: EPI Data Centre Training Framework, Principle of Data transmission through fiber optic cables, Fiber-optic communication
NEW QUESTION # 50
What is the best practice for cutting holes in the raised floor tile?
- A. Draw a cross on the tile and when making a cut-out do not touch a line and avoid the corners.
- B. Anywhere as data centre tiles are designed to allow cut-outs anywhere.
- C. Cut the tiles at the corner so the pedestals can be used as a vertical cable manager.
- D. Draw a line in the middle of the tile and never touch the line when making the cut.
Answer: A
Explanation:
According to the Raised Floor Installation Manual, the best practice for cutting holes in the raised floor tile is to draw a cross on the tile and when making a cut-out do not touch a line and avoid the corners1. This ensures that the structural integrity and load-bearing capacity of the tile are not compromised. Cutting holes anywhere, touching the line, or cutting the corners can weaken the tile and cause it to crack or collapse1.
Additionally, the manual recommends using a drill press or a reciprocating saw with a metal or bi-metal cutting blade, and deburring all sharp edges1.
References: 1: Raised Floor Installation Manual, E. Recommended Cutting Tools, Page 1
NEW QUESTION # 51
Which formula is correct?
- A. Power Factor = Volt Ampere ' Watt
- B. Volt-Ampere = Watt * Power Factor
- C. Watt = VoIt-Ampere / Power Factor
- D. Watt = Volt-Ampere * Power Factor
Answer: D
NEW QUESTION # 52
Which type of Humidifier is composed of water-filled canister containing electrodes?
- A. Steam Canister Humidifier
- B. Infrared Humidifiers
- C. Ultrasonic Humidifier
- D. Water Canister Humidifier
Answer: A
Explanation:
A steam canister humidifier is a type of humidifier that uses electricity to heat water in a canister containing electrodes. The water conductivity and the water level determine the amount of current and steam production.
The steam canister humidifier is also known as an electrode boiler humidifier or an electrode steam humidifier123.
References: 1: EPI Data Centre Professional (CDCP) Reference Materials, page 192: Electrode and resistive type humidifiers compared | steamovap technologies inc3: Know-How | Electrode Steam Humidifier - Condair Group.
NEW QUESTION # 53
systems are designed specifically to protect the structure of a building.
- A. Inergen
- B. Water sprinkler
- C. Total Flooding
- D. Pro-inert
Answer: B
Explanation:
Water sprinkler systems are designed to protect the structure of a building from fire by suppressing or extinguishing the flames with water. Water sprinkler systems are typically installed in the ceiling or walls of a building and are activated by heat or smoke detectors. Water sprinkler systems can reduce the risk of fire spreading and causing structural damage to the building.
References:
*EPI Data Centre Professional (CDCP®) Preparation Guide, page 28
*Fire Protection Systems for Data Centers | EPI
NEW QUESTION # 54
What is the purpose of a service corridor?
- A. It provides a safe, vented and secure area where standby generators can operate safely.
- B. To create a secure and conditioned environment where media can be stored in a controlled manner.
- C. It is a generic name for pathways leading to other rooms that contains facility supporting equipment like the UPS room, battery room, generator room etc.
- D. It provides a secure area where supporting facilities can be serviced and monitored on a 24x7 basis without disturbing the computer room.
Answer: D
Explanation:
A service corridor is a dedicated space within or adjacent to a data centre that allows access to the supporting facilities, such as power, cooling, fire suppression, security, and cabling systems, without interfering with the computer room operations. A service corridor helps to isolate the noise, vibration, heat, and dust generated by the supporting facilities from the sensitive equipment in the computer room. A service corridor also enhances the safety and efficiency of the maintenance and monitoring activities, as well as the flexibility and scalability of the data centre design.
References: EPI Data Centre Training Framework, CDCP Preparation Guide, Service Corridors Definition | Law Insider
NEW QUESTION # 55
......